Udvalgte virksomhedsoplysninger fra CVR via Datafordeleren, suppleret med tidligere LEI-oplysninger. Personligt ejede virksomheder vises uden gadeadresse og postnummer. Mangelfulde og beskyttede poster kan være udeladt. Udvalget er ikke et historisk totalarkiv over alle danske CVR-numre.

Bekendtgørelse om frivillig forudgående gennemsigtighed · 28. august 2025

Delivery of Gradient Coil for human magnetic resonance imaging

Danmarks Tekniske Universitet - DTU offentliggjorde 28. august 2025 en bekendtgørelse om frivillig forudgående gennemsigtighed om »Delivery of Gradient Coil for human magnetic resonance imaging«. Den samlede kontraktværdi er 129.967 EUR.

Type
Bekendtgørelse om frivillig forudgående gennemsigtighed
Ordregiver
Danmarks Tekniske Universitet - DTU
By
Kgs. Lyngby
Offentliggjort
28. august 2025
Kontrakttype
Varer
Procedure
Udbud med forhandling uden forudgående offentliggørelse
Kontraktværdi
129.967 EUR
CPV-koder
38520000
TED-nummer
561640-2025

Beskrivelse fra ordregiveren

DTU needs to purchase a uniaxial resonant head insert gradient coil for animal and human magnetic resonance imaging (MRI), particularly for hydrogen and hyperpolarized carbon-13 MRI. We aim for 3D mapping of brain metabolites with a time resolution of around a second for calculation of metabolic rates. This requires gradient performance exceeding that of clinical scanners. To drive the gradient coil at the needed slew rate and current with an MRI gradient amplifier, it needs to be resonant, so it amplifies the output at specific frequencies multi-fold. An integrated capacitor bank is needed to make the coil resonant at around 10 kHz for carbon-13, and 20 kHz for hydrogen to make the data acquisition quiet for fMRI (Versteeg et al, Magn Reson Med. 2022;87:1062–1073). To compensate for the low gyromagnetic ratio of carbon-13, an efficiency of around 0.3 mT/m/A is needed. At 10 kHz, it must sustain maximum voltages and currents of 1.8 kV and 300 A (4.8 kV and 225 A at 20 kHz). The maximum duty cycle needs to be near 100% during the lifetime of the carbon MRI signal, i.e., 2 minutes. The application shall include functional MRI with visual stimulation, so the gradient coil needs to be open in front of the subject eyes. Since the coil will only be relevant for a patient sub-group, it needs to be mountable and configured within an hour to enable flexible use of the scanner with intermittent coil use required to enable clinical translation. The coil needs to be designed, built and equipped with safety measures (sensors) so it can be approved for human use, even though CE labelling is not a requirement. Market research has shown, that the only supplier of resonant human-suited head insert gradient coils is Futura Composites BV that can fulfill the requirements above. Therefore, DTU intends to issue a purchase order to the company.

Andre bekendtgørelser fra Danmarks Tekniske Universitet - DTU

Kilde

Bekendtgørelsen er offentliggjort i TED (nr. 561640-2025). Teksten er ordregiverens egen. Udbudsmaterialet og eventuelle rettelser findes hos ordregiveren eller i TED. Genbrug med kildeangivelse (Kommissionens afgørelse 2011/833/EU).