Udvalgte virksomhedsoplysninger fra CVR via Datafordeleren, suppleret med tidligere LEI-oplysninger. Personligt ejede virksomheder vises uden gadeadresse og postnummer. Mangelfulde og beskyttede poster kan være udeladt. Udvalget er ikke et historisk totalarkiv over alle danske CVR-numre.

Bekendtgørelse om frivillig forudgående gennemsigtighed · 23. juli 2026

2026-0988030 - OPM-MEG

Aarhus Universitet offentliggjorde 23. juli 2026 en bekendtgørelse om frivillig forudgående gennemsigtighed om »2026-0988030 - OPM-MEG«.

Type
Bekendtgørelse om frivillig forudgående gennemsigtighed
Ordregiver
Aarhus Universitet
By
Aarhus C
Offentliggjort
23. juli 2026
Kontrakttype
Varer
Procedure
Andet (én fase)
CPV-koder
38000000
Udførelsessted (NUTS)
DK042
TED-nummer
509230-2026

Beskrivelse fra ordregiveren

The contract concerns the purchase of an OPM-MEG. The contracting authority intends to award the contract concerning the delivery of an OPM-MEG to CFIN, Aarhus University through negotiated procedure without prior publication, as the supplies can only be provided by a particular economic operator for technical reasons. These technical reasons are specifically related to uniqueness in terms of form, function, or performance – and cannot be obtained on the open market in a comparable form – i.e., only one supplier is able to provide the instrument in question. The Center of Functionally Integrative Neuroscience (CFIN) at Aarhus University requires an Optically Pumped Magnetometer MEG (OPM-MEG) system to support an active program of human neuroimaging research. The research involves recording brain activity non-invasively in healthy adults, clinical populations, and pregnant women (fetal neurophysiology). CFIN plans to also record MEG from small children in the near future. These applications have the following requirements to be technically and ethically viable within an adequate failsafe safety margin: • Sensor surface temperature ≤46°C after 30 minutes of continuous operation mounted on the head or abdomen to avoid burn hazards and to allow the sensors to be arranged more densely and enable longer data collection sessions. • Sensor noise floor <18 fT/√Hz to ensure reliable detection of weak neural magnetic signals targeted by current and proposed research projects. • Sensor dimensions ≤16 × 16 × 40 mm to enable dense sensor coverage of target brain regions and fetal measurements. • Full-head coverage extending to C1 to enable reliable cerebellar and posterior fossa measurements. No other supplier on the market offers this solution in one system. Only the HEDscan 96-sensor from FieldLine meets all mentioned essential requirements.

Andre bekendtgørelser fra Aarhus Universitet

Kilde

Bekendtgørelsen er offentliggjort i TED (nr. 509230-2026). Teksten er ordregiverens egen. Udbudsmaterialet og eventuelle rettelser findes hos ordregiveren eller i TED. Genbrug med kildeangivelse (Kommissionens afgørelse 2011/833/EU).