Udvalgte virksomhedsoplysninger fra CVR via Datafordeleren, suppleret med tidligere LEI-oplysninger. Personligt ejede virksomheder vises uden gadeadresse og postnummer. Mangelfulde og beskyttede poster kan være udeladt. Udvalget er ikke et historisk totalarkiv over alle danske CVR-numre.

Bekendtgørelse om frivillig forudgående gennemsigtighed · 30. maj 2024

[Andor Dragonfly microscope] to [Department of Biology, University of Copenhagen]

University of Copenhagen offentliggjorde 30. maj 2024 en bekendtgørelse om frivillig forudgående gennemsigtighed om »[Andor Dragonfly microscope] to [Department of Biology, University of Copenhagen]«. Den samlede kontraktværdi er 2.658.000 kr.

Type
Bekendtgørelse om frivillig forudgående gennemsigtighed
Ordregiver
University of Copenhagen
By
Copenhagen K
Offentliggjort
30. maj 2024
Kontrakttype
Varer
Procedure
Udbud med forhandling uden forudgående offentliggørelse
Kontraktværdi
2.658.000 kr.
CPV-koder
38510000
Udførelsessted (NUTS)
DK011
TED-nummer
320457-2024

Beskrivelse fra ordregiveren

As many of the projects in our section is centred around 4D live sampling of wholemount tissues, fast acquisition is crucial to visualize subcellular-, cellular-, and tissue-scale processes at high spatiotemporal resolution. These needs are only met by spinning discs confocal microscopes. Specific assets of the Andor Dragonfly microscope compare with other spinning discs are: 1) Andor instruments use the patented Borealis® uniform illumination, which delivers uniform illumination in the full field of view using an array of microlenses. This allows high spatial resolution with reduced artefacts due to heterogeneity in illumination along the edges. 2) Andor uses High Power Laser Engine (HLE) with multimode fibre and solid state diode lasers. HLE offers tunable laser power: high power for faster acquisition from fixed samples and gentle illumination for live cell samples. 3) Andor provides a basic license for the Imaris software which is a great tool for 3D rendering, 4D segmentation, and fundamental quantitative bioimage analysis. 4) Andor provides dual camera ports with two highly sensitive sCMOS camera. This will reduce the acquisition time 20x and can significantly reduce photobleaching and phototoxicity upon live-cell imaging. The cameras come with SRRF-stream+ algorithm that provides super-resolved images.

Andre bekendtgørelser fra University of Copenhagen

Kilde

Bekendtgørelsen er offentliggjort i TED (nr. 320457-2024). Teksten er ordregiverens egen. Udbudsmaterialet og eventuelle rettelser findes hos ordregiveren eller i TED. Genbrug med kildeangivelse (Kommissionens afgørelse 2011/833/EU).