Bekendtgørelse om indgået kontrakt · 24. april 2026
Dielectric-barrier discharge ionization interface for Orbitrap mass spectrometer
Danmarks Tekniske Universitet - DTU offentliggjorde 24. april 2026 en bekendtgørelse om indgået kontrakt om »Dielectric-barrier discharge ionization interface for Orbitrap mass spectrometer«. Den samlede kontraktværdi er 74.030 EUR.
- Type
- Bekendtgørelse om indgået kontrakt
- Ordregiver
- Danmarks Tekniske Universitet - DTU
- By
- Kgs. Lyngby
- Offentliggjort
- 24. april 2026
- Kontrakttype
- Varer
- Procedure
- Udbud med forhandling uden forudgående offentliggørelse
- Kontraktværdi
- 74.030 EUR
- CPV-koder
- 38433100, 38000000, 38400000, 38430000, 38433000
- Udførelsessted (NUTS)
- DK012
- TED-nummer
- 280963-2026
Beskrivelse fra ordregiveren
DTU Sustain is working with environmental forensics and metabolomic investigations to study the fate and occurrence of chemicals and small molecules dispersed into the environment. The work involves creating untargeted metabolomic and non-target chemical analysis data recordings of trace level chemicals in complex environmental samples using liquid chromatography hyphenated with ultrahigh-resolution mass spectrometry. To be able to make new and novel molecular characterizations and discoveries, DTU wants to procure a dielectric-barrier discharge ionization interface capable of being hyphenated with an existing Orbitrap mass spectrometer. Dielectric-barrier discharge ionization is a soft-ionization method is a promising alternative to traditional mass spectrometry ionization techniques. As an ambient ionization technique, dielectric-barrier discharge operates via a non-thermal plasma generated between two electrodes separated by a dielectric barrier. Unlike traditional ionization sources, it produces a rich mixture of reactive species (e.g., metastable atoms, radicals, photons, and ions) capable of ionizing a broader range of analytes through soft ionization mechanisms (e.g. proton transfer, adduct and Penning ionization). In addition, the combined system must be/have; • Fitted to an Orbitrap Exploris series high-resolution mass spectrometer • Enable for soft ionization of polycyclic aromatic hydrocarbons • Capable of desorption and analyzing a solid-phase microextraction fiber in the interface • A plug-n-play ion source that does not require calibration • Capable of real-time recording of volatile organic chemicals • Soft ionization mechanism based cold plasma, proton transfer and ultra-violet light • No or reduced in-source fragmentation • Potential for coupling with gas and liquid chromatography
Andre bekendtgørelser fra Danmarks Tekniske Universitet - DTU
- Parkeringssystem Danmarks Tekniske Universitet - DTU · 11. november 2026 · frist 27. november 2026 · ca. 2.000.000 kr.
- ICP-MS/MS system for elemental analysis of high-salinity brines Danmarks Tekniske Universitet - DTU · 5. november 2026
- Procurement of Biomark X9 system Danmarks Tekniske Universitet - DTU · 30. oktober 2026
- Tilkøb af HelioxVT-indsats til eksisterende TeslatronPT cryostat Danmarks Tekniske Universitet - DTU · 29. oktober 2026
- Parkeringssystem Danmarks Tekniske Universitet - DTU · 27. oktober 2026 · frist 11. november 2026 · ca. 2.000.000 kr.
- The procurement of the Supply, Installation and Commissioning of a Focused Ion Beam Scanning Electron Microscope (FIB-SEM) with Gallium Ion Source Danmarks Tekniske Universitet - DTU · 15. oktober 2026 · frist 16. november 2026
Kilde
Bekendtgørelsen er offentliggjort i TED (nr. 280963-2026). Teksten er ordregiverens egen. Udbudsmaterialet og eventuelle rettelser findes hos ordregiveren eller i TED. Genbrug med kildeangivelse (Kommissionens afgørelse 2011/833/EU).